{"product_id":"ansed-diagnostic-solutions-ansed-5-gas-diagnostic-system-kit-ansed-kane-ega5","title":"ANSED KANE-EGA5 5-Gas Exhaust Analyzer Kit | Portable Diagnostics","description":"\u003ch2\u003e\n\u003cstrong\u003eAnsed Diagnostic Solutions ANSED 5-Gas Diagnostic System Kit ANSED-KANE-EGA5\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe process of diagnosing general performance, drivability, no code and catalytic converter issues can be complex and frustrating. Modern OBDII systems may miss problems too small or infrequent to set a code. In seconds, the Exhaust Gas Analyzer will detect problems too marginal to be detected by an onboard computer or a scan tool.Experienced technicians agree that an Automotive Exhaust Gas Analyzer is an integral part of their diagnostic toolbox. One quick test of the exhaust gases emitted from the tailpipe helps reduce diagnostic time, verify repairs are complete, reduce comebacks, and increase overall profitability and customer satisfaction. With the ANSED Exhaust Gas Diagnostics System, there are no more charts and graphs, no more black magic calculations. The ANSED Exhaust Gas Diagnostics Software interprets the exhaust gases and their interactions and provides a top-down list of suggested problems and solutions in order of probability. And, KANE LINK to connect to KANE LIVE apps and to the optional KANE-IRP3 Infra-red printer. The ANSED Exhaust Gas Diagnostics System is the most complete and comprehensive solution on the market today. Tests HC, O2, CO, CO2, NOx and Lambda; All readings LIVE, except NOx and LAMBDA calculated; Self-calibrating, no cal-gas required; Dyno not required for NOx testing.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e \u003c\/p\u003e\n\u003ch3 style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003ciframe width=\"835\" height=\"401\" src=\"https:\/\/www.youtube.com\/embed\/gzQqMI1BzMk\" title=\"Tech tips for the Exhaust Gas Analyzer AutoPlus 5\"\u003e\u003c\/iframe\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eKey Features: Large Graphic Display, Easy to read all gases and Lambda on one screen, no scrolling\u003c\/li\u003e\n\u003cli\u003eErgonomic Design Keypad, Simple and easy to navigate and use, Bluetooth or USB Cable ready, Links analyzer easily to PC to use with KANE LINK\u003c\/li\u003e\n\u003cli\u003eVariable Pump Speed, Allows for adjustment of the pump speed, which can then improve battery life\u003c\/li\u003e\n\u003cli\u003eOptional Hi-Speed Print Capability, Use with the KANE-IRP3 hi-speed printer with rechargeable battery\u003c\/li\u003e\n\u003cli\u003eProbe, Equipped with the EP1 Hi-Temperature Probe, with 4m Neoprene tubing, 350mm insertion depth. Key Benefits: Completely portable, handheld, Sample exhaust gas in the shop or on a road test, NOx testing without a dynometer\u003c\/li\u003e\n\u003cli\u003eLow cost to operate and maintain, Operates off internal rechargeable battery, Self-calibrating, no cal-gas required, Water trap and filter visible\u003c\/li\u003e\n\u003cli\u003eFast diagnostic times.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable style=\"margin-left: auto; margin-right: auto;\" xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" cellspacing=\"0\" cellpadding=\"0\" dir=\"ltr\" border=\"1\" data-sheets-root=\"1\" data-sheets-baot=\"1\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"237\"\u003e \u003ccol width=\"230\"\u003e \u003ccol width=\"264\"\u003e \u003ccol width=\"221\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eParameter\u003c\/td\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon Monoxide\u003cbr\u003e(High Range NDIR)\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e+\/- 5 % of reading\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e*1\u003c\/sup\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e0-10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e+\/- 0.3 % volume \u003c\/span\u003e\u003csup\u003e*1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e0-25 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHydrocarbon\u003cbr\u003e(NDIR)\u003c\/td\u003e\n\u003ctd\u003e1 ppm\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e+\/- 5 % of reading\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e*1\u003c\/sup\u003e\u003c\/p\u003e\n\u003cp\u003e+\/- 12 ppm volume\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e*1\u003c\/sup\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e0-5000 ppm\u003cbr\u003eOver-range: 10,000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon Dioxide\u003cbr\u003e(NDIR)\u003c\/td\u003e\n\u003ctd\u003e0.1 %\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e+\/- 0.3% of reading \u003c\/span\u003e\u003csup\u003e*1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e0-20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitric Oxide*²\u003cbr\u003e(fuel cell)\u003c\/td\u003e\n\u003ctd\u003e1 ppm\u003c\/td\u003e\n\u003ctd\u003e0-1500ppm +\/-5% or 25ppm;\u003c\/td\u003e\n\u003ctd\u003e0-5000ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon Monoxide\u003cbr\u003eCorrected COK\u003c\/td\u003e\n\u003ctd\u003e0.01%\u003c\/td\u003e\n\u003ctd\u003eCalculated\u003c\/td\u003e\n\u003ctd\u003e0-15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLambda\u003cbr\u003eAFR (Petrol)\u003cbr\u003e(LPG)\u003c\/td\u003e\n\u003ctd\u003e0.001\u003cbr\u003e00.01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.8 – 1.2\u003cbr\u003e11.76 – 17.64\u003cbr\u003e12.48 – 18.72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ctable data-sheets-baot=\"1\" data-sheets-root=\"1\" border=\"1\" dir=\"ltr\" cellpadding=\"0\" cellspacing=\"0\" xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" style=\"margin-left: auto; margin-right: auto;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"237\"\u003e \u003ccol width=\"309\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor response Time\u003c\/td\u003e\n\u003ctd\u003eNominal 20 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarm up\u003c\/td\u003e\n\u003ctd\u003eLess than 2 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-programmed Fuels\u003c\/td\u003e\n\u003ctd\u003ePetrol\/Gasoline, LPG Diesel and CNG.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePC connection\u003c\/td\u003e\n\u003ctd\u003eVia RS 232 port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData-Logging\u003c\/td\u003e\n\u003ctd\u003e200 Tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003cbr\u003eWeight\u003cbr\u003eHandset\u003cbr\u003eProbe\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e1.2 kg (2.65 pounds)\u003cbr\u003e240mm x 165mm x 65mm (9.45 x 6.5 x 2.56”)\u003cbr\u003eInsertion depth 350mm x Diameter 15mm\u003cbr\u003eClip handle to secure to exhaust, 4m long hose\u003cbr\u003eVarious probes available including high temperature\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Operating Range\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e+5\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC to +50\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC \/ 10% to 90% RH non-condensing\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003eMinimum: 0°C\u003cbr\u003eMaximum: +45°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Charger\u003c\/td\u003e\n\u003ctd\u003eInput: 100-240 V\u003cbr\u003e\u003cbr\u003eOutput: 12 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalyzer battery run time\u003c\/td\u003e\n\u003ctd\u003e6+ hours from full charge.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Documents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0364\/5725\/0948\/files\/KANE-EGA5_User_Manual_1.pdf?v=1695673486\" target=\"_blank\"\u003eManual\u003c\/a\u003e\u003c\/p\u003e","brand":"Ansed Diagnostic Solutions","offers":[{"title":"Default Title","offer_id":51584316571942,"sku":"ASDANSED-KANE-EGA5","price":4907.67,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/2764\/9830\/files\/Ansed-diagnostic-solutions-ANSED-5-gas-diagnostic-system-kit-ANSED-KANE-EGA5.png?v=1760934966","url":"https:\/\/primeindustrialusa.com\/products\/ansed-diagnostic-solutions-ansed-5-gas-diagnostic-system-kit-ansed-kane-ega5","provider":"Prime Industrial USA","version":"1.0","type":"link"}