{"product_id":"cb-woo-2878030416a4f1466d8d3253bafbe3c44612d9556aadc38d86c6b9d6b34bcef4","title":"Drolet Eco-55 Pellet Stove With 3'' Ground Floor Kit DP00070KVG","description":"\u003ch2\u003e\u003cstrong\u003eDrolet Eco-55 Pellet Stove With 3'' Ground Floor Kit DP00070KVG\u003c\/strong\u003e\u003c\/h2\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eEasy to use and maintain, the Eco-55 pellet stove is ideal for heating spaces up to 2,000 ft². It features intuitive electronic control and easy to use thermostatic control. Cleaning is a breeze, with access to components that are removable without tools. Certified at only 0.96 g\/h, the Eco-55 produces up to 39,260 BTU\/h, and provides clean and efficient heating.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIncluded\u003c\/strong\u003e: 4'' Vortex pellet ground floor kit (one stove adapter, one tee, one 12\", 18\" and 36\" length of black stove pipe, one 9\" length slip section, one 90° elbow, one wall pass-thru, two wall supports and one jet cap), blower, ceramic glass, ash lip\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBurn time up to 51 hours (up to 120 hours with the optional hopper extension)\u003c\/li\u003e\n\u003cli\u003eHopper capacity of 60 lb\u003c\/li\u003e\n\u003cli\u003eTop-feed burner\u003c\/li\u003e\n\u003cli\u003eEPA 2020 certified\u003c\/li\u003e\n\u003cli\u003eProudly made in Canada\u003c\/li\u003e\n\u003cli\u003eLimited lifetime warranty\u003c\/li\u003e\n\u003cli\u003eCertified for mobile home and alcove installation\u003c\/li\u003e\n\u003cli\u003eWeight : 303 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel type\u003cspan\u003e (\u003cspan\u003e12\u003c\/span\u003e)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003ePellet (Premium grade or better)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended heating area\u003cspan\u003e (\u003cspan\u003e10\u003c\/span\u003e)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e500 - 2,000 ft²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHopper capacity\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e60 lb (27 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum burn time\u003cspan\u003e (\u003cspan\u003e10\u003c\/span\u003e)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e51 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum heat input rate \u003cspan\u003e(\u003cspan\u003e4\u003c\/span\u003e)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e39,260 BTU\/h (11.5 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum overall heat output rate\u003cspan\u003e (\u003cspan\u003e5\u003c\/span\u003e)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e6,648 BTU\/h (1.95 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum overall heat output rate\u003cspan\u003e (\u003cspan\u003e5\u003c\/span\u003e)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e28,540 BTU\/h (8.36 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum average overall efficiency (HHV)\u003cspan\u003e\u003cspan\u003e (\u003cspan\u003e6\u003c\/span\u003e)\u003c\/span\u003e\u003cspan\u003e (\u003cspan\u003e8\u003c\/span\u003e)\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e70.3 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum average overall efficiency (LHV)\u003cspan\u003e\u003cspan\u003e (\u003cspan\u003e6\u003c\/span\u003e)\u003c\/span\u003e\u003cspan\u003e (\u003cspan\u003e7\u003c\/span\u003e)\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e75.8 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptimum efficiency\u003cspan\u003e (\u003cspan\u003e2\u003c\/span\u003e)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e78.4%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptimum heat transfer efficiency\u003cspan\u003e (\u003cspan\u003e9\u003c\/span\u003e)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e73 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBurn rate\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1.2 - 4.7 lb\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage particulate emission rate\u003cspan\u003e (\u003cspan\u003e3\u003c\/span\u003e)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e0.96 g\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage CO\u003cspan\u003e (\u003cspan\u003e11\u003c\/span\u003e)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e7.6 g\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage electrical power consumption for ignition cycle \u003cspan\u003e(\u003cspan\u003e1\u003c\/span\u003e)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e3.02A (360 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage electrical power consumption for continuous operation \u003cspan\u003e(\u003cspan\u003e1\u003c\/span\u003e)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1.3 - 2.5A (51 - 140 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003eMedium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcove installation approved\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMobile home approved\u003c\/td\u003e\n\u003ctd\u003eYes, with fresh air intake\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh-efficiency certified appliance\u003c\/td\u003e\n\u003ctd\u003eYes, EPA 2020 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombustion technology\u003c\/td\u003e\n\u003ctd\u003eTop-feed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaffle type\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlue outlet diameter\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChimney diameter\u003c\/td\u003e\n\u003ctd\u003e3\" | 4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of chimney\u003c\/td\u003e\n\u003ctd\u003eULC\/ORD-C441, CAN\/ULC S609, UL 641 (TYPE L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e25 1\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall dimension (Height)\u003c\/td\u003e\n\u003ctd\u003e32 5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall dimension (Depth)\u003c\/td\u003e\n\u003ctd\u003e29 1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePremium quality blower included (CFM)\u003c\/td\u003e\n\u003ctd\u003e176 CFM included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage and frequency\u003c\/td\u003e\n\u003ctd\u003e120 VAC \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise level at 6 feet\u003c\/td\u003e\n\u003ctd\u003e47 dBa (+\/- 3 dBa) - 60 dBa (+\/- 3 dBa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDoor type\u003c\/td\u003e\n\u003ctd\u003eSingle, glass with cast iron frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlass type\u003c\/td\u003e\n\u003ctd\u003eCeramic glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlass surface - W x H\u003c\/td\u003e\n\u003ctd\u003e15 3\/4\" x 8 1\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCanadian Standard (emissions)\u003c\/td\u003e\n\u003ctd\u003eCSA B415.1-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSA Standard (emissions)\u003c\/td\u003e\n\u003ctd\u003eEPA, ASTM E2779\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCanadian Standard (safety)\u003c\/td\u003e\n\u003ctd\u003eULC S627\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSA Standard (safety)\u003c\/td\u003e\n\u003ctd\u003eUL 1482, ASTM E1509\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertified according to applicable standards\u003c\/td\u003e\n\u003ctd\u003eBy an accredited laboratory (CAN\/USA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eLimited lifetime\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping weight\u003c\/td\u003e\n\u003ctd\u003e277 lb (126 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eClearance To Combustibles\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCanada\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eUnited States\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance - Back wall\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance - Side wall\u003c\/td\u003e\n\u003ctd\u003e6\"\u003c\/td\u003e\n\u003ctd\u003e6\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance - Corner\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance - Base of the unit to ceiling**\u003c\/td\u003e\n\u003ctd\u003e48\"\u003c\/td\u003e\n\u003ctd\u003e48\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe information given on the certification label affixed to the appliance always overrides the information published in any other media (owner's manual, catalogues, flyers, magazines and\/or web sites).\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003eSome appliances have been tested with a low ceiling. Before setting up your unit, refer to the installation manual.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eUnless stated otherwise, measures were taken directly at the main power source and include all electrical components present in the appliance.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOptimum overall efficiency at a specific burn rate (LHV).\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eThis appliance is officially tested and certified by an independent agency.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBased on the maximum burn-rate and a dry energy value of pellet at 8,600 BTU\/lb.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAs measured per CSA B415.1-10 stack loss method.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEfficiency based on radiated and delivered heat when allowing cycling from high to low burn to simulate thermostat demand.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLower Heating Value of the fuel.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHigher Heating Value of the fuel.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e9The optimum heat transfer efficiency is for the low burn rate (using HHV) and represents the appliance’s ability to convert the energy contained in the solid fuels into energy transferred to the room in the form of heat and does not take into account the chemical losses during combustion.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRecommended heating area and maximum burn time may vary subject to location in home, chimney draft, heat loss factors, climate, fuel type, feed rate, fuel level, and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature considering that the space configuration and the presence of heat distribution systems have a significant impact in making heat circulation optimum.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGrades of pellet fuel are determined by organizations such as Pellet Fuels Institute (PFI), ENplus and CANplus.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Documents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0513\/0564\/4209\/files\/EN-45876I_2018-01-16_2-inman.pdf?v=1659633749\" target=\"_blank\"\u003eInstallation Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0513\/0564\/4209\/files\/45876O_2018-01-16_8-opman.pdf?v=1659633749\" target=\"_blank\"\u003eOperation Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n","brand":"Prime Industrial USA","offers":[{"title":"Pellet Stove Only","offer_id":54535198605606,"sku":"DP00070KVG","price":2144.0,"currency_code":"USD","in_stock":true},{"title":"Fresh Air Intake Kit (+$60.00)","offer_id":54535198638374,"sku":"DP00070KVG+AC01240","price":2183.0,"currency_code":"USD","in_stock":true},{"title":"Hopper Extension (+$212.00)","offer_id":54535198671142,"sku":"DP00070KVG+AC01393","price":2282.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/2764\/9830\/files\/cbimg-54d111772a86962471d5fd46.jpg?v=1794867157","url":"https:\/\/primeindustrialusa.com\/products\/cb-woo-2878030416a4f1466d8d3253bafbe3c44612d9556aadc38d86c6b9d6b34bcef4","provider":"Prime Industrial USA","version":"1.0","type":"link"}