{"product_id":"cb-woo-cebaaa73037aee26120d4cbbffa7415aeaddf98a6dcb6676eb8d8201801ec87f","title":"SMA STP 30-US-50 Sunny Tripower X String Inverter","description":"\u003ch2\u003eSMA STP 30-US-50 Sunny Tripower X String Inverter\u003c\/h2\u003e\n\u003cp\u003eThe SMA STP 30-US-50 Sunny Tripower X String Inverter is engineered to set a new benchmark in versatile, intelligent energy management for commercial PV systems. Its advanced features promise future-proof system designs and maximum energy yields.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFeatures three MPP trackers with SMA ShadeFix optimization for exceptional design flexibility.\u003c\/li\u003e\n\u003cli\u003eIntegrated System Manager powered by ennexOS for simplified monitoring and control.\u003c\/li\u003e\n\u003cli\u003eAdvanced safety with SunSpec PLC signal for module-level shutdown and DC AFCI arc-fault protection.\u003c\/li\u003e\n\u003cli\u003eEnhanced energy yields with SMA Smart Connected proactive service and support.\u003c\/li\u003e\n\u003cli\u003eRobust design catering to future expansions and dynamic grid support.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnology and Overview\u003c\/h2\u003e\n\u003cp\u003eEquipped with SMA’s ennexOS platform, the STP 30-US-50 provides innovative cross-sector management of energy resources, driving efficiency and reliability in commercial solar energy systems.\u003c\/p\u003e\n\u003ch2\u003eInstallation and Compatibility Overview\u003c\/h2\u003e\n\u003cp\u003eInstallation is streamlined thanks to the inverter's integrated system manager, which facilitates centralized commissioning and system control for up to 5 inverters.\u003c\/p\u003e\n\u003ch2\u003eBenefits and Applications Overview\u003c\/h2\u003e\n\u003cp\u003eOptimize your investment with the STP 30-US-50, designed for maximum yield and minimal operational costs, making it a go-to solution for commercial solar installations.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel No.\u003c\/td\u003e\n\u003ctd\u003eSTP 30-US-50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum PV array power\u003c\/td\u003e\n\u003ctd\u003e45000 Wp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum input voltage\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPP voltage range\u003c\/td\u003e\n\u003ctd\u003e515 V to 800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum input voltage \/ initial input voltage\u003c\/td\u003e\n\u003ctd\u003e150 V \/ 188 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating input current \/ short-circuit current per MPP tracker\u003c\/td\u003e\n\u003ctd\u003e24 A \/ 37.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of independent MPP trackers \/ string inputs per MPP tracker\u003c\/td\u003e\n\u003ctd\u003e3 \/ 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal output power\u003c\/td\u003e\n\u003ctd\u003e30000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum apparent power\u003c\/td\u003e\n\u003ctd\u003e30000 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC voltage\u003c\/td\u003e\n\u003ctd\u003e480 V \/ 277 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC voltage range\u003c\/td\u003e\n\u003ctd\u003e244 V to 305 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated grid frequency \/ range\u003c\/td\u003e\n\u003ctd\u003e60 Hz \/ 50 Hz to 66 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum output current\u003c\/td\u003e\n\u003ctd\u003e36 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower factor at rated power \/ adjustable displacement\u003c\/td\u003e\n\u003ctd\u003e1 \/ 0.8 overexcited to 0.8 underexcited\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput phases \/ line connection\u003c\/td\u003e\n\u003ctd\u003e3 \/ 3-(N)-PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHarmonics (THD)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 3 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCEC efficiency\u003c\/td\u003e\n\u003ctd\u003e98.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad rated DC disconnect\u003c\/td\u003e\n\u003ctd\u003eStandard feature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGround fault monitoring \/ grid monitoring\u003c\/td\u003e\n\u003ctd\u003eStandard feature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC reverse polarity protection \/ AC short-circuit protection\u003c\/td\u003e\n\u003ctd\u003eStandard feature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAll-pole sensitive residual-current monitoring unit\u003c\/td\u003e\n\u003ctd\u003eStandard feature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class \/ overvoltage category\u003c\/td\u003e\n\u003ctd\u003eI \/ III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC AFCI arc-fault protection\u003c\/td\u003e\n\u003ctd\u003eStandard feature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSunSpec PLC signal for rapid shutdown\u003c\/td\u003e\n\u003ctd\u003eStandard feature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC surge protection type 2 \/ DC surge arrester type 1+2\u003c\/td\u003e\n\u003ctd\u003eOptional feature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W\/H\/D)\u003c\/td\u003e\n\u003ctd\u003e728 mm \/ 762 mm \/ 266 mm (28.7 in \/ 30 in \/ 10.5 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Weight\u003c\/td\u003e\n\u003ctd\u003e35 kg \/ 77 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature range\u003c\/td\u003e\n\u003ctd\u003e-25°C to +60°C (?13°F to +140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise emission (typical)\u003c\/td\u003e\n\u003ctd\u003e59 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology \/ cooling concept\u003c\/td\u003e\n\u003ctd\u003eTransformerless \/ OptiCool (forced convection, variable speed fans)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure protection rating\u003c\/td\u003e\n\u003ctd\u003eType 4X (as per UL 50E)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrosivity classification according to IEC 61701\u003c\/td\u003e\n\u003ctd\u003eC5*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum permissible value for relative humidity (non-condensing)\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting type\u003c\/td\u003e\n\u003ctd\u003eVertical rack \/ wall mount to 15° from horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC connection \/ AC connection\u003c\/td\u003e\n\u003ctd\u003eAmphenol H4 Plus \/ spring-cage terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED indicators (status \/ fault \/ communication)\u003c\/td\u003e\n\u003ctd\u003eStandard feature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork interfaces: Ethernet \/ WLAN\u003c\/td\u003e\n\u003ctd\u003eStandard feature(2 ports)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData protocols: SMA Modbus \/ SunSpec Modbus \/ Speedwire\u003c\/td\u003e\n\u003ctd\u003eStandard feature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMulti-function relay \/ Extension module slot \/ Digital inputs\u003c\/td\u003e\n\u003ctd\u003eStandard feature (6 inputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSMA ShadeFix string level optimization\u003c\/td\u003e\n\u003ctd\u003eStandard feature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated I-V curve diagnostics 1)\u003c\/td\u003e\n\u003ctd\u003eStandard feature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Plant Control \/ Q on Demand 24\/7\u003c\/td\u003e\n\u003ctd\u003eStandard feature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSMA Smart Connected (proactive monitoring and service support)\u003c\/td\u003e\n\u003ctd\u003eStandard feature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard warranty\u003c\/td\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional warranty extensions (total warranty coverage cannot exceed 20 years)\u003c\/td\u003e\n\u003ctd\u003e+5 years, +10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificates and approvals\u003c\/td\u003e\n\u003ctd\u003eUL 62109-1, UL 1699B Ed. 1, CAN\/CSA 22.2 No. 62109-1:16 \/ 62109-2:16, PV Rapid\u003cbr\u003eShutdown System Equipment in accordance with UL1741:2021\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFCC compliance\u003c\/td\u003e\n\u003ctd\u003eFCC Part 15 Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid interconnection standards\u003c\/td\u003e\n\u003ctd\u003eUL 1741 SB, IEEE 1547:2018, compliance to SRDs: CA Rule 21, HECO Rule 14H, ISO-NE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum number of supported inverters \/ energy meters\u003c\/td\u003e\n\u003ctd\u003e5 \/ 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum system power PV inverters (nominal AC power)\u003c\/td\u003e\n\u003ctd\u003e150 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCentralized commissioning of all devices in the system\u003c\/td\u003e\n\u003ctd\u003eStandard feature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote parameterization of SMA devices\u003c\/td\u003e\n\u003ctd\u003eStandard feature (via Sunny Portal powered by ennexOS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSMA Dynamic Power Control (e.g. zero export \/ Volt-VAr) 2)\u003c\/td\u003e\n\u003ctd\u003eOptional feature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"Prime Industrial USA","offers":[{"title":"Default Title","offer_id":68057241780298,"sku":"USIN100-0512","price":2299.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0785\/8398\/8298\/files\/cbimg-96e0e84480d44b7b7001affe.jpg?v=1795288581","url":"https:\/\/primeindustrialusa.com\/products\/cb-woo-cebaaa73037aee26120d4cbbffa7415aeaddf98a6dcb6676eb8d8201801ec87f","provider":"Prime Industrial USA","version":"1.0","type":"link"}