{"product_id":"cb-woo-d1ea2968c28b5bfc9b3dc7625b88248b7bb4ea0e77a0223df655c422a2e80e1d","title":"Ventis ME300 Wood Burning Fireplace, Zero Clearance VB00001","description":"\u003ch2\u003e\u003cstrong\u003eVentis ME300 Wood Burning Fireplace, Zero Clearance VB00001\u003c\/strong\u003e\u003c\/h2\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe ME300 fireplace is designed for ambiance. It generates enough heat in the event of a power failure. The unit includes a blower for heat circulation and a firescreen to allow the enjoyment of an open fire.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned mainly for ambiance; incomparable view on the flames\u003c\/li\u003e\n\u003cli\u003eIncludes fire screen doors, 8\" Ventis stainless steel anchor plate, fresh air intake adapter, and 176 CFM blower\u003c\/li\u003e\n\u003cli\u003eFirebox size: 4.25 sq. ft.\u003c\/li\u003e\n\u003cli\u003eDouble-doors made of ceramic glass with cast-iron frame\u003c\/li\u003e\n\u003cli\u003eHeats up to 1,500 sq. ft.\u003c\/li\u003e\n\u003cli\u003eFlue size: 8\"\u003c\/li\u003e\n\u003cli\u003eMinimum chimney height from base of fireplace: 15'\u003c\/li\u003e\n\u003cli\u003eNon-catalytic combustion technology\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAppliance Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003ctable\u003e\n\u003ccolgroup\u003e\n\u003ccol\u003e\n\u003ccol\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFuel type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003eDry cordwood\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRecommended heating area\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003eUp to 1,500 ft²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOverall firebox volume\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e4.25 ft³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eBurn rate\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u0026gt; 5 kg\/h (\u0026gt; 11 lb\/h)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAverage particulate emission rate\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e2.9 g\/kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThis appliance is officially tested and certified by an independent agency.\u003c\/li\u003e\n\u003cli\u003eRecommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eGeneral Features\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003ctable\u003e\n\u003ccolgroup\u003e\n\u003ccol\u003e\n\u003ccol\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePremium quality blower included (CFM)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e176 CFM included\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCertified according to applicable standards\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eCAN\/USA accredited laboratory\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFlue outlet diameter\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRecommended chimney diameter\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eType of chimney\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eULC S604, ULC S629, UL S610, UL 103 HT (2100 °F)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMinimum chimney height\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e15\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOverall dimension (Width)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e41 1\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOverall dimension (Height)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e43 5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOverall dimension (Depth)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e28 1\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDoor type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eDouble, glass with cast iron frame\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDoor opening size (Width)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDoor opening size (Height)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e16 1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eGlass type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003eCeramic glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eGlass surface - W x H\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e28 1\/2\" x 17 1\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFirebox size (Width)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e23 1\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFirebox size (Height)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e18 5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFirebox size (Depth)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e11 3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum log length\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e20\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eLog positioning\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eLoading over width\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eHigh-efficiency certified appliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003eExempt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCanadian Standard (safety)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003eULC-S610\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eUSA Standard (safety)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003eUL 127\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eShipping weight\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e511 lb (232 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCombustion technology\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003eNon-catalytic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eUSA Standard (emissions)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eASTM 2515 \/ ASTM 2558\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCanadian Standard (emissions)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eASTM 2515 \/ ASTM 2558\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Documents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0100\/7917\/4734\/files\/Ventis_Fireplace_Catalogue.pdf?v=1660582127\" target=\"_blank\"\u003eProduct Catalogue\u003c\/a\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0100\/7917\/4734\/files\/VB00001_Specification_Sheet.pdf?v=1660764556\" target=\"_blank\"\u003eAppliance Dimensions\u003c\/a\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0100\/7917\/4734\/files\/VB00001_Installation_and_Operation_Manual.pdf?v=1660764556\" target=\"_blank\"\u003eInstallation and Operation Manual\u003c\/a\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0100\/7917\/4734\/files\/AC01347_4in_Fresh_Air_Intake_Adapter.pdf?v=1660579495\" target=\"_blank\"\u003eFresh Air Intake Adapter Installation Instructions\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n","brand":"Prime Industrial USA","offers":[{"title":"Default Title","offer_id":54546413945126,"sku":"VB00001","price":2177.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/2764\/9830\/files\/cbimg-5a4cbbb7fdc7ac1f40f388ec_0c86963a-b575-42fd-be68-385ec04f8211.gif?v=1794940977","url":"https:\/\/primeindustrialusa.com\/products\/cb-woo-d1ea2968c28b5bfc9b3dc7625b88248b7bb4ea0e77a0223df655c422a2e80e1d","provider":"Prime Industrial USA","version":"1.0","type":"link"}